About this Model:
  • Max Capacity: 50g Moisture Content Readability[d]: 0.001% 
  • 7” Graphic Color Touchscreen 
  • 250 °C Halogen Drying Lamp
  • Dry Mass Determination (4) Functions & Weighing Modes 
  • RS232, USB-A, USB-B, Ethernet, Wi-Fi
Download Datasheet

Shipping Lead Time: 4 - 6 Weeks

Radwag MA X7.A.WH Moisture Analyzer

Radwag MA X7.A.WH Moisture Analyzer

MA.X7.A series

is equipped with innovative system: the drying chamber can be opened and closed automatically using button or proximity sensors.Such solution allows:

  • Maintaining moisture analyzer clean – operator does not touch moisture analyzer’s housing.
  • Removing any shocks caused by manual closing of the chamber – the chamber closes automatically and always with the same intensity.
  • Achieving high repeatability of opening and closing the drying chamber.
  • Enhancing drying process automation.
  • Enhancing safety of operation by eliminating contact with hot components of drying chamber.
  • Improving operation ergonomics.

Capacity and
Temperature

MA.X7.A maximum capacity ranges from 50g/0.1mg to 210g/0.1mg. Moisture content is measured with the 0.01%accuracy (0.001 % for samples bigger than 1.5g).The maximum drying temperature is 160˚C (there is an optional  moisture analyzer with 250˚C maximum temperature).

An additional element for moisture analyzers that improves their functionality is a water vapor permeability determination set used in tanning industry for determining hygienic properties of leather.

The results

The results obtained using the moisture analyzer (the final result of the drying process):

  • % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage,
  • % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated,
  • % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process,
  • – the sample mass after drying.

MA.X7.A series

is equipped with innovative system: the drying chamber can be opened and closed automatically using button or proximity sensors.Such solution allows:

  • Maintaining moisture analyzer clean – operator does not touch moisture analyzer’s housing.
  • Removing any shocks caused by manual closing of the chamber – the chamber closes automatically and always with the same intensity.
  • Achieving high repeatability of opening and closing the drying chamber.
  • Enhancing drying process automation.
  • Enhancing safety of operation by eliminating contact with hot components of drying chamber.
  • Improving operation ergonomics.

Capacity and
Temperature

MA.X7.A maximum capacity ranges from 50g/0.1mg to 210g/0.1mg. Moisture content is measured with the 0.01%accuracy (0.001 % for samples bigger than 1.5g).The maximum drying temperature is 160˚C (there is an optional  moisture analyzer with 250˚C maximum temperature).

An additional element for moisture analyzers that improves their functionality is a water vapor permeability determination set used in tanning industry for determining hygienic properties of leather.

The results

The results obtained using the moisture analyzer (the final result of the drying process):

  • % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage,
  • % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated,
  • % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process,
  • – the sample mass after drying.
Datasheet
Maximum capacity [Max] 50  g
Readability [d] 1  mg
Tare range -50  g
Adjustment external  
Maximum sample weight 50  g
Heating module halogen  
Moisture content repeatability +/-0.05% (sample ~ 2g), +/-0.01% (sample ~ 10g)  
Moisture content readability 0.001%  
Drying temperature range Max 250  °C
Leveling system manual  
Display 7″ graphic colour touchscreen  
Weighing chamber automatic  
Maximum sample height 20  mm
Weighing pan dimensions ø90, h= 8  mm
Packaging dimensions 476×381×346  mm
Net weight 5.2  kg
Gross weight 6.5  kg
Protection class IP 43  
Display mode %MC, %DC, %ATRO MC, %ATRO DC, g, g/kg MC, g/kg DC, -%MC  
Drying method 4 drying profiles (standard, fast, step, mild)  
Finish mode 4 modes (automatic, manual, time-defined, user-defined)  
Additional functions sample traceability  
Communication interface RS232¹, USB-A, USB-B, Ethernet, Wi-Fi®  
Power supply 100V – 120V AC 50/60Hz or 200V-240V AC 50/60Hz  
Power consumption 6 W  
Heating module power 450 W  
Operating temperature +10 — +40  °C
Mass indication control External mass standard 50 g, 100 g, 200 g (depending on the type of moisture analyzer)  
Internal adjustment For .IC models only, GLP report  
External adjustment For all models, GLP report  
Drying temperature control One- or two-point, depending on the drying profile (equipment: GT105k-12/Z Control Thermometer)  
Moisture content indication control Certified MV Test Set  
Internal / External adjustment Depending on the type of moisture analyzer, GLP report  
Drying temperature adjustment Three-point adjustment at defined temperatures, programmable values (equipment: GT105k-12/Z Control Thermometer)  

Functions